MEASUREMENT OF LIVER BLOOD FLOW


Abstract views: 45 / PDF downloads: 20

Authors

  • Avni GÖKALP Gaziantep Üniversitesi Tıp Fakültesi Genel Cerrahi ABD. Yrd.Doç.Dr.
  • Hayri ERKOL Gaziantep Üniversitesi Tıp Fakültesi Genel Cerrahi ABD. Yrd.Doç.Dr.
  • Necdet AYBASTI Gaziantep Üniversitesi Tıp Fakültesi Genel Cerrahi ABD. Doç,Dr.
  • İbrahim SANAL Gaziantep Üniversitesi Tıp Fakültesi Genel Cerrahi ABD. Doç,Dr.

DOI:

https://doi.org/10.58600/eurjther.19920301-1241

Keywords:

Blood flow, tissue perfusion, portal blood flow, hepatic blood flow, Doppler ultrasound, Doppler laser, x-ray angiography

Abstract

The study of hepatic hemodynamics is of importance in understanding both hepatic physiology and diseases as well assessing the effects of portosystemic shunting and liver transplantation. The liver has the most complicated circulation of any organ many physiological and pathological processes can affect it (1,2). This review surveys the methods available for assessing liver blood flow, examines the different parameters being measured and outlines problems of applicability and interpretation for each technique. The classification of these techniques is to some extent arbitrary and several so called 'different' methods may share certain common principles. The methods reviewed have classified into two groups (Table I):Those primarily reflecting flow thorough discrete vessels or to the whole organ and those used to assess local microcirculatory blood flow. All techniques have their advantages and disadvantages and in some situations a combination may provide the most information. in addition, because of the many factors affecting liver blood flow and sinusoidal perfusion, readings in a single subject may vary depending on positioning, recent food intake, anxiety, anesthesia and drug therapy. This must be borne in mind if different studies are to be meaningfully compared .

Metrics

Metrics Loading ...

References

- Richardson P.D.I. and Withrington P.G.: Liver blood flow l.lntrinsic and nervous control of liver blood flow. Gastroenterology, 81:159-173, 1981.

- Richardson P.D.I. and Withrington P.G.: Liver blood flow II.Effects of drugs and hormones on liver blood flow.Gastroenterology, 81:356-375, 1981.

- Fabre P.: Utilisation des forces electromotrices d'enrigistrement des variations de vitesse des liquids conducteurs:Un nouvel hemodromograph sans palette dans le sang. C.R.Acad.Sci.Paris, 194:1097-1098, 1932.

- Webster J.G.: Measurement of flow and volume of blood. In:Medical instrumentation:Application and Design. Ed.Webster J.G.Houghton, Mifflin, Boston, 1978, ch.8.

- Harper A.M,Lorimer A.R, Thomas D.L:Methods of measuring blood flow.In:Scientific Foundations of Anesthesia, Ed.Scurr C, Feldman, S.,Heinemann, London, 1974,pp. 28-44.

- Khouri E.M.and Gregg D.E:Miniature electromagnetic flowmeter applicable to coronary arteries. J.Appl.Physiol., 18:224, 1963.

- Wyatt D.G.: Blood flow and blood velocity measurement in vivo by electromagnetic induction. Med.Biol.Eng.Comput., 22:193-211, 1984.

- Meisner H. and Messmer K.: Significance and limitations of electromagnetic blood flowmetry, Experimental and Clinical Results.Prog.Surg.,8:124-144, 1970.

- Drapanas T., Kluge D.N., Schenk W.G.: Measurement of hepatic blood flow by bromsulphalein and by the electromagnetic flowmeter. Surgery, 48:1017-1021, 1960.

- Price J.B., Britton R.C, Peterson L.M, Reilly J.W, Voorhees A.R.: The validity of chronic hepatic blood flow measurements obtained by electromagnetic flow meter. J.Surg.Res. V(7):313-317, 1965.

- Bradley S.E., Inglefinger F.J., Bradley G.P., Curry J.J.: The estimation of hepatic blood flow in man.J.Clin.Invest., 24:890, 1945.

- Satomura S:Study of the flow pattern in peripheral arteries by ultrasonics, Nihon Onkyo-gakkai, Shi, 15:151, 1959.

-Taylor K.J.W. and Burns P.N.: Duplex Doppler scanning in the pelvis and abdomen. Ultrasound Med.Biol.11:643-658, 1985.

- Okazaki K., Miyazki S. and Onishi S.: Noninvasive measurements of portal blood flow., Gastroenterology, 93:656-657, 1987.

- Baker D.W.: Pulsed ultrasonic Doppler blood-flow sensing., IEEE., Trans.Sonics.Ultrasonic, 17 (3):170, 1970.

- Burns P.N.: The physical principles of Doppler and spectral analysis. J.Clin.Ultrasound., 15:567- 590, 1987.

- Koslin D.B. and Berland L.L.: Duplex Doppler examination of the liver and portal venous system. J.Clin.Ultrasound, 15:675-686, 1987.

- Ohnishe K.,Saito M.,Koen H.,Nakayama T.,Normura F.,Okuda K: Pulsed Doppler flow as a criterion of portal venous velocity:Comparison with cineangiographic measurements. Radiology, 154:495-498, 1985.

- Sovak M., Soulen R.L. and Reichle F.A.:Blood flow in the human portal vein.A cineradiographic method using particulate contrast medium. Radiology, 99:531-536, 1971.

- Ackroyd N., Lane R. and Dart L.: Colour-coded carotid Doppler imaging:An angiographic comparison of 324 bifurcation., Aust.NZ.J.Surg., 54:509-517, 1984.

- Okazaki K,Miyazaki M,Onishi S.and lto, K:Effect of food intake and various extrinsic hormones on portal blood flow in patients with liver cirrhosis demonstrated by pulsed doppler with the octoson. Scand. J.Gastroenterol., 21:1029-1038, 1986.

- Moriyasu F., Nishida O. and Ban, N. et al.: Congestion index of the portal vein. A.J.R., 146:735- 739, 1986.

- Nelson R.C,Lovett K.E,Chezmar J.L,Moyers J.H,Torres W.E,Murphy F.B.and Bemardino M.E.: Comparison of pulse Doppler sonography and angiography in patients with portal hypertension. AJR., 149:77-81, 1987.

- Barbara B., Bolondi L. and Bosch J. et al.:The value of Doppler US in the study of hepatic hemodynamics.J.Hepatol., 10:353-355, 1990.

- Miyateke K.,Okamoto M.,Kinoshita N.,lzumi S.,Owa M., Taka o S.,Sakakibara H.and Nim ura Y.: Clinical applications of a new type of real-time two-dimensional Doppler flow imaging system. Am.J.Cardiol., 54:857-868, 1984.

- Seifelian A.M., Young J.M. and Hobbs K.E.F.: Quantitative assessment of portal vein blood flow by duplex ultrasoun scanning. Clin. Radiol.,39:681, 1988.

- Dick R.: Portal and hepatic venous system. in: Techniques in diagnostic radiology. Eds., G.H. Whitehouse and D.S.Worthtington. Blackwell Scientific Publications, 1983, pp.165-182.

- Hillal S.K.: The determination of the blood flow by a radiographic technique. Am.J.Roentgenol., 96:896-906, 1966.

- Seifalian A.M., Hawkes D.J., Colchester A.C.F. and Hobbs K.E.F.: A new algorithm for deriving pulsatile blood flow wave forms tested using stimulated dynamic angiographic data. Neuroradiology, 31:263-269, 1989.

- Colhester A.C.F.: The Effect of changing Pa CO, on cerebral artery calibre estimated by a new technique of dynamic quantitative digital angiography.Phd.Thesis, University of London, 1985.

- Lantz B.M.T., Link D.P., Foerster J.M. and Holcroft J.W.: Angiographic determination of splanchnic blood flow.Acta Radiologica Diagnosis, 21:3-10, 1980.

- Kedem D. ,Smith D. W,Dean R.H.and Brill A.B:Velocity distribution and blood flow measurements using videodensitometric methods., Invest.Radiol., 13(1):46-56, 1978.

- Sovak M.,Soulen R.L.and Reichle F .A.: Blood flow in the human portal vein. A cineradiographic method using particulate contrast medium., Radiology, 99:531-536, 1971.

-Iwanaga T.,Koyannagi N .and Sugimachi K. :Validity of ultrasonic duplex system for measurement of the portal blood flow in patients with liver disease., Japanese J. Surgery, 17(1):58-59, 1987.

- Reichle A., Sovak M., Soulen R.L. and Rosemond G.P.: Portal vein blood flow determination in the unanesthetized human by umbilicoportal cannulation J.Surg.Res., 12:146-150, 1972.

- Du Boulay G.H., Brunt J., Colchester A., Hawkes D., Wallis A. and Wicks D.: Volume flow measurement of pulsa tile flow by digitised cine angiography. Ar.ta Radiologica, Suppl(13):59-62, 1987.

- Bettman M.A., Morris T.W.: Recent advances in contrast agen,. RCNA., 24(3):347-357, 1986.

- Cope C.: Minipuncture angiography., RCNA., 24(3):359-367, 1986.

- Carr H.Y. and Purcell E.M.: Phys.Rev., 94:630, 1950.

- Garroway A.N.: Velocity measurements in flowing fluids by NMR., J.Phys.D:Appl.Phys., 7:159- 163, 1974.

- Hahn E.L.: Detection of sea water motion by nuclear procession., J.Geophys.Res., 65:776-777, 1960.

- Hawkes R.C.,Holland G.N.,Moore W.S. and Worthington B.S.:Nuclear magnetic resonance (NMR)tomography of the brain:A preliminary clinical assessment with demonstration of pathology., J.Comput.Assist.Tomogr., 4:577-586, 1980.

- Waluch V.and Bradley,W.G.:NMR even echo rephasing in slow laminar flow. J.Comput.Assist. Tomogr., 4:594-598, 1984.

- Bradley W.G. and Waluch V.: Blood flow:Magnetic resonance imaging., Radiology, 154:443-450, 1985.

- Ridgway J. P., Tumbull L. W. and Smith M. A.: Demonstration of pulsatile cerebrospinal fluid flow using magnetic resonance phase imaging. Bri.J.Radiology, 60:423-427, 1987.

- Shimizu K., Matsuda T., Sakurai T., Fujita A., Ohara H., Okamura S., Hashimoto S., Mano H., Kawai C.and Kiri M.:Visualisation of moving fluid: Quantitative analysis of blood flow velocity using mr imaging. Radiology, 159:195-199, 1986.

- West D.J., Tarnawski M., Graves M.J., Taylor M.G.Padayachee T.S.,Ayton V.T.and Smith M.A.: Blood flow imaging by magnetic resonance., Medicamundi, 33(3):101-111, 1988.

- Bradley S.E. and Curry J.J: The estimation of hepatic blood flow in man. J.Clin.lnvest., 24:890- 897, 1945.

- Fick A.:Uber die Messung des Blutquantums in den Herzventrikeln., S.B.Phys- med.Ges.Wurzb., 21:171-180, 1870.

- Brauer R., Pessotti R.L. and Krebs J.S.: The distribution and excretion of 355-labelled Sulfobromophatelein-sodium administered to dogs by continuous infusion.,J.Clin.lnvest., 34:35- 40, 1955.

- Caesar J., Shaldon S., Chiandussi L. and Sherlock S.: The use of indocyanin green in the measurement of hepatic blood flow and as a test of hepatic function., Oin.Sci., 21:43-57, 1961.

- Grainger S.L., Keeling P.W.N., Brown I.M.H., Marigold J.H. and Thompson R.P.H.: Clearance and non-nvasive determination of the hepatic extraction of indocyanin green in baboons and men., Clin.Sci., 64:307-412, 1983.

- Clements O., West R. and Elias E.: Comparison of the two methods of estimating liver blood flow in patients with liver disease., Gut, 27:A613-A614, 1986.

- Combes B.: Estimation of hepatic blood flow in man and dogs by ''I-labelled Rose Bengal: Simultaneous comparison with sulfobromophatelein sodium., J.Lab.Clin.Med., 56:537-543, 1960.

- Pirttiaho H.,Pitkanen U .,Rajasalmi M.and Ahonen A. :Comparison of three methods of measuring liver blood flow., Acta Radiological Diagnosis., 21:534-535, 1980.

- Kety S.S.: Measurement of regional circulation by the local clearence of radioactive sodium., Am.Heart.J.,38:321-328, 1949.

- Lassen N.A.: Cerebral blood flow in man determined by the use of radioactive Krypton., Acta. Physiol.Scand., 33:30-49, 1955.

- Lassen N.A.: Muscle blood flow in normal man and in patients with intermittent claudication evaluated by simultaneous '''Xe and ' 4Na clearances.,J.Clin.lnvest., 43:1805-1812, 1964.

- Dobson E.L. and Jones H.B.: The behaviour of intravenously injected particulate material. lts rate of disappearence from the blood stream as a measure of liver blood flow., Acta.Med.Scand., 144:71-85, 1952.

- Dobson E.L., Wamer G.F ., Finney C.R. and Johnston M.E.: The measurement of liver circulation by means of the colloid disappearence rate. I.Liver blood flow in man., Circulation, 7:690-695, 1953.

- Riddel A.G., Griffiths D.B., Mc Allister J.M. and Osborn S.B: The measurement of liver blood flow with colloidal radiogold (<9' Au). Clin.Sci., 16:315-324, 1957.

- Fauvert R., Benhamou S. and Loverdo A.: La clearance de I'or colloidal radio-actif (198-Au). I. Valeurs normales et valeurs pathologiques., Rev.Franc.Etud.Clin.Biol., 3:762-766, 1958.

- Flemming J.S.,Humpries N.L.M.,Karran J.S.,Goddard B.A.and Ackery D.M.:In vivo assessment of hepatic-arterial and portal-venous components of liver perfusion.: Concise communication., J.Nucl.Med., 22(1):18-21, 1981.

- Wright E.P,Barber R. W.and Ritson A:Relative hepatic arterial and portal flow in liver scintigraphy Nucl.Med.Commun., 3:273-279, 1982.

- Flemming J.S., Ackery D.M., Walmsley B.H. and Karran J.S.: Scintigraphic estimation of arterial and portal blood supplies to the liver., J.Nucl.Med., 24:1108-1113, 1983.

- Parkin A.C., Robinson P.J., Baxter P., Leveson 5.H., Wiggin P.A. and Giles G.R.: Liver perfusion scintigraphy-Method, Normal range and laparatomy correlation in 100 patients.Nucl.Med. Commun., 4:395-402, 1983.

- Britten A.J., Flemming J.5., Flowerdew A.0.5., Hunt T.M., Taylor I., Karran J.5. and Ackery D.M.: A comparison of three indices of relative hepatic perfusion derived from dynamic liver scintigraphy.,Clin.Phys.Physiol.Meas., 11:45-51, 1990.

- Sarper R.,Fajman W.A.,Rypins E.B.,Henderson J.M., Tarcan T.A.,Galambos J.T.and Warren W.D: A noninvasive method for measuring portal venous/total hepatic blood flow by hepatosplenic radionuclide angiography., Radiology, 141:179-184, 1981.

- Biersack H.J., Thelen M.andSchulz D.:Die sequentielle hepatospleno szintigraphie zurquantitiven beurteilung der leberduchblutung., Fortschre, Roentgenstr., 126:47-52, 1977.

- Rypins E.B., Fajman W. and Sarper R.: Radionuclide angiography of the liver and spleen. A non- invasive method of portal venous/total hepatic blood flow ratio and portosystemic shunt patency. Am.J.Surg., 142:574-579, 1981.

- Birtch A.G., Casey B.H. and Zakheim R.M.: Hepatic blood flow measured by the 1 'Kr clearance technique., Surgery, 62:174-180, 1967.

- Mackenzie R.J., Leiberman D.P., Mathie R.T.: Liver blood flow measurement. The interpretation of '"Xe clearance curves., Acta.Chir.Scand., 142:519-525, 1976.

- Heymann M.A., Payne B.D., Hoffınan J.I.E. and Rudolph A.M.: Blood flow measurements with radionuclide labelled particles., Prog.Cardiovas.Dis., 20:55-79,1977.

- Romeo J.M., Lopez-Farre A., Martin-Paradero V. and Lopez-Novoa J.M.: Hepatic hemodynamic changes after portocaval anastomosis in normal, cirrhotic and chronic prehepatic portally hypertensive rats., Br.J.Surg., 77:335-338, 1990.

- Greenway C. V. and Oshiro G.: Intrahepatic distribution of portal and hepatic arterial blood flows in anesthetized cats and dogs and the effects of portal occlusion, raised venous pressure and histamine., J.Physiol., 227:473-485, 1972.

- Arvidsson O., Svensson H. and Haglung U.: Laser Doppler flowmetry for estimating liver blood flow., Am.J.Physiol., 254:G471-476, 1988.

- Gouma D.J., Coelho J.C., Schlegel J., Fisher J.D., Li Y.G. and Moody F.G.: Estimation of hepatic blood flow by hydrogen gas clearance., Surgery, 99(4):439-444, 1986.

- Ackerman N.B., Lien W.N., Kondi E.5. and Silverman N.A.: The blood supply of experimental liver metastases., Surgery, 66:1067-1072, 1969.

- Archer S.G., Gray B.N.: Vascularisation of small liver metastases., Br.; Surg., 76:545-548, 1989.

- Nott D.M., Grime S.J., Yates J., Day D.W., Baxter J.N. and Cooke T.!. · Changes in the hepatic perfusion index during the development of experimentalhepatic tumours., Br.J.Surg., 76:259-263, 1989.

- Romeo J.M., Lopez-Farre A., Martin-Paradero V. and Lopez-Novoa J.M.: Hepatic hemodynamic changes after portocaval anastomosis in normal, cirrhotic and chronic prehepatic portally hypertansive rats., Br.J.Surg., 77:335-338, 1990.

- Gibbs F.A.: A thermoelectric blood flow recorder in forofaneedle.,Proc.Soc.Exp.Biol.Med.31:141- 146, 1933.

- Grabner G. and Neumayer A.: A continuous recording method for the estimation of liver blood flow in man.In:Proceedings Harey Tercentenary Congress.Ed.J.McMichael., pp.386-392, 1958.

- Grayson J. and Kinnear T.: Observations on temperature, blood flow and heat production in the human liver in relation to enviroment and to glucose and insulin administiration., Clin.Sci., 22: 125-140, 1962.

- Newman W.H., Curley M.G., 5ummit 5.C., Bowma'n H.F/, DelHomme G. and DittmarA.: Simultaneous measurements of tissue perfusion and oxygenation., Annual Intemational Conf. IEEE Eng.Med.Biol.Soci., 12(3):1036-1037, 1990.

- Grayson J. and Johnson D.H.: The effect of adrenalin and noradrenalin on the liver blood tlow., J.Physiol., 120:73-94, 1953.

- Aukland K., Bower . B.F .. and Berliner R.W.: Measurement of blood flow with hydrogen gas., Circulation Research, 14:164-187, 1964.

- Fieschi C., Bozzao L. and Agnoli A.: Regional clearance of hydrogen. as a measure of cerebral blood flow., Acta Neurol. Scand., 14(Suppl):46-52, 1965

- Fieschi C., Bozzao L.,Agnoli A., Nardini M.and Barto!ini A.:The hydrogen method of measuring local blood flow in subcortical structures of the braiıdncluding a comparative study with the 14-C aıi.tipyrine method., Exp.Brain Res., 7:III-119, 1969.

- Bozzao L., Agnoli A., Bartolini A. and Fieschi C.: Local cerebral blood flow measured by clearaıi.ce curves of hydrogen gas.In:Cerebral Blood Flow, Ed.H. Lechner, Thomas Springfield, 1970.

- Kety 5.5.: The theory and application of the exchange of inert gas at the lung and tissue., Pharmacol.Rev., 3:1-41, 1951.

- Young W.:'H-clearance measurement of blood flow: A Review of techniques and polarographic principles., Stroke, 11:552-564, 1980.

- Nishivaki H., Ohira' M., Boku T., Ishikawa J., Yata K. and Umeyama K.: The measurement of hepatic circulation before and after orthotopic liver transplantation in dog by using transit time blood flow meter and H-2 clearance method., Nippon-Geka-Gekkai-Zasshi, 90(2):243-249, 1989.

- Baumberger J.P. and Goodfriend R.B.: Determination of arterial oxygen tension in man by equilibration through intact skin., Federation Proc., 10:10-11, 1951.

- Clark L.C.: Monitor and control of blood and tissue oxygen tension., Tran.Am.Soc.Artif.Intem. Organ., 2:41-48, 1956.

- Hunt T.K., Rabkin J., Jensen J.A., Jonsson K., SmittenK.V. and Goodson W.H.:Tissue oxymetry: An interim report., World J.Surg., 11:126-132, 1987.

- Piasecki C.: First experimental results with the oxygen electrode as a local blood flow sensor in canine colon., Br.J.Surg., 72:452-453, 1985.

- Piasecki C.: A new method for the assesment of gut viability., Br.J.Surg., 68:319-322, 1981.

- Ji S., Leamasters J.J., Christenson V. and Thurman R.G.: 5elective increase in pericentral oxygen gradient in perfused rat liver following ethanol treatment., Pharmacology Biochemistry and Behaviour, 19:439-442, 1983.

-Kram H.B. and Shoemaker W.C.: Method of intraoperative assessment of organ perfusion and viability using a miniature oxygen sensor., Am.J.Surg., 148:404-407, 1984.

-Piasecki C., Seifalian A.M.: Continuous intraoperative monitoring of hepatic blood perfusion using a noninvasive surface electrode., Dig.Dis.Sci., 35(3):399-405, 1990.

-Riva C., Ross B. and Benedek G.: Laser Doppler measurements of blood flow in capillary tubes and retinal arteries.,Invest.Ophtalmol., 11:936-944, 1972.

-Nilson G.E., Tenland T.and Obser P.A.:Evaluating of a laser Doppler flowmeter for measurement of tissue blood flow., IEEE.Trans.Biomed.Eng., 27:597-604, 1980.

-Bonner R.and Nossal R.:Model for laser Doppler measurements of blood flow in tissue., Applied Optics, 20:2097-2107, 1981.

-DamberJ.E., Lindahl O., SelstanG. and Tenland T.: Testicular blood flow measured with a laser Doppler flowmeter:Acute effects of catecholamines., Acta Physiol.Scand., 115(2):209-215, 1982.

-Swain I.D. and Grant L.J.: Methods of measuring skin blood flow., Phys.Med.Biol., 34:151-175, 1989.

-Shepheard A.P., Riedel G.L. and Ward W.F.: Laser Doppler measurement of blood flow within the intestinal wall and on the surface of the liver.ln:Microcirculation of the alimentary tract, Eds. A.Koo, R.F.Lam,L.M.Swaje World Scientific, Singapore, pp.115-129, 1983.

-Bloom N.D., Kroop E., Sadjadi M., Jacobs R., Ramaswamy G. and Akerman N.B., Enhancement of fumour blood flow and tumoricidal effect of Doxorubicin by intraportal epinephrine in experimental liver metastasis., Arch.Surg.,122:1269-1272, 1987.

Downloads

Published

1992-01-01

How to Cite

GÖKALP, A., ERKOL, H., AYBASTI, N., & SANAL, İbrahim. (1992). MEASUREMENT OF LIVER BLOOD FLOW. European Journal of Therapeutics, 3(1), 78–93. https://doi.org/10.58600/eurjther.19920301-1241

Issue

Section

Review Articles