Using diode laser (810 nm) in the second-stagesurgery: Case report

İkinci faz implant cerrahisinin diyot lazer (810 nm) ile tedavisi: Olgu sunumu


Abstract views: 55 / PDF downloads: 27

Authors

  • Işıl Büyükhatipoğlu Prosthodontist, Deva Hospital, Gaziantep
  • Bilge Yüksel Aydeyer Prosthodontist Dentist, Gaziantep
  • Fatih Sarı Department of Prosthetic Treatment, Dentistry Faculty, Gaziantep University, Gaziantep

DOI:

https://doi.org/10.5152/EurJTher.2016.013

Keywords:

Diode laser, second stage implant surgery

Abstract

The implant surgery consists of two distinct techniques, the transmucosal, also known as “one-stage” and the “two-stage” technique. This case report presents dental implant uncovering with a diode laser for second stage implant surgery following the healing period of the first stage implant surgery for a missing lateral incisor.

Metrics

Metrics Loading ...

References

Buser D, Mericske-Stern R, Dula K, Lang NP. Clinical experience with one-stage, non-sub merged dental implants. Adv Dent Res 1999;13:153-61.

Adell R, Leukholm U, Branemark PI. Surgical procedures. in: Branemark PI, Zarb G, Albrektsson T (eds). Tissue Integrated Prothesis-Surgical Procedures, Quintessence Publishing Co, Chicago 1985;S.223-5.

Vanheusden A. Impression technics in implantology. Rev Belge Med Dent 2001;56(3):189-203.

Garg AK, Vicari A. Concepts in impressions for dental implantology. Implant Soc 1994;5(2):11-6.

Pirnat S. Versatility of an 810 nm diode laser in dentistry: an overview. J Laser Health Acad 2007;4:1-9.

Gianfranco S, Francesco SE, Paul RJ. Erbium and diode lasers for operculisation in the second phase of implant surgery: a case series. Timisoara Med J 2010;60:117-23.

Romanos G, Nentwig GH. DiodeLaser (980 nm) in oral and maxillofacial surgical procedures: observations based on clinical applications. J Clin Laser Med Surg 1999;17(5):193-7.

Gantijo I, Navarro RS, Haypek S, Ciamponi AL, Hadded AE. The applications of diode and Er: YAG lasers in labial frenectomy in infant patients. J Dent Child (Chic) 2005;72(1):10-5.

Romanos GE, Everts H, Nentwig GH. Effects of diode and Nd: YAG laser irradiation on titanium discs: A scanning electron microscope examination. J Periodontol 2000;71:810-5.

Romanos GE. Treatment of periimplant lesions using different laser systems. J Oral Laser Appl 2002;2:75-81.

El-Kholey. Efficacy and safety of a diode laser in second-stage implant surgery: a comparative study. Int J Oral Maxillofac Surg 2014;43:633-8.

Fornaini C, Merigo E, Vescovi P, Bonanini M, Antonietti W, Leoci L, et al. Different laser wavelengths comparison in the second-stage implant surgery: an ex vivo study. Laser Med Sci 2014 Jul 3.

Martin E. Lasers in dental implantology. Dent Clin North Am 2004;48:999-1015.

Downloads

Published

2023-05-10

How to Cite

Büyükhatipoğlu, I., Yüksel Aydeyer, B., & Sarı, F. (2023). Using diode laser (810 nm) in the second-stagesurgery: Case report: İkinci faz implant cerrahisinin diyot lazer (810 nm) ile tedavisi: Olgu sunumu. European Journal of Therapeutics, 22(3), 171–174. https://doi.org/10.5152/EurJTher.2016.013

Issue

Section

Case Reports